Ultra Seal® Well Bond

Print Friendly, PDF & Email

Well Information

VR 24 CASE HISTORY INITIAL TEST 10 3/4 X 13 5/8

  • Tested 10 3/4″ x 13 5/8″ casing void to 5,000 psi.

  • The void would only pressure up to 200 psi with our test unit pumping 25 Cubic Inches Per Minute.

  • Tied in test pump and flushed plastic injection, seal tite product and valve grease from void and both injection port fittings until gaining clean fluid returns.

  • Began pumping Well Bond into 10 3/4 x 13 5/8″ void. As pressure rose, we began taking returns on the injection port manifold positioned 90 degrees to the left of the void test fitting. The valve was closed after receiving clean Well Bond product.
  • 12 Hours after injection, the 10 3/4 x 13 5/8″ casing void was retested.

  • Applied 5000 psi for pressure test for 30 minutes on 10 3/4 x 13 5/8″ void. Test passed.